Emporia Vue: Gen 2 3-PHASE Whole Home Energy Monitor

Emporia Vue: Gen 2 3-PHASE Whole Home Energy Monitor

Free Shipping
Emporia Energy

View Details

Emporia has developed the next generation of the Vue Energy Monitor. Committed to bringing the best value at the lowest price possible, the Vue provides everything you need to monitor your entire home's energy usage in real time. See how much electricity your home is using anywhere, anytime.

Features and Benefits:

  • READY FOR 3-PHASE: Includes an extra 200A Sensor for light commercial 3-phase/4-wire electrical systems (up to 415Y/240VAC & less than 600A ). Does not work with 3-phase/3-wire systems (Delta systems with no neutral)

    NO NEED TO PURCHASE AN EXTRA SENSOR

  • INSTALLS IN CIRCUIT PANEL of most homes with clamp-on sensors; although it doesn't typically work in panels with access only to busbars. INSPECT YOUR ELECTRICAL PANEL for compatibility. 

  • 24/7 ENERGY MONITORING: Monitor your home's real power anywhere, anytime to prevent costly repairs, conserve energy, and save costs. Monitor solar / net metering. PROTECTED BY A 1-YEAR WARRANTY.

  • LOWER YOUR ELECTRIC BILL: Gauge real-time spending and get actionable notifications to understand where you can save costs.

  • REAL-TIME ENERGY DATA: REQUIRES 2.4 GHz WIFI WITH AN INTERNET CONNECTION to monitor energy use with iPhone / Android / Web app. Vue sensors collect energy data and are accurate from ±2%. The Vue is UL and CE Listed for your safety. 1 second data is only available in the app (when actively open) and retained 3 hours. Minute and hour data are retained in the cloud. 1 minute data is retained 7 days, 1 hour data is retained indefinitely. Export cloud data whenever you want in the app.
  • APPLIANCE MONITORING WITHOUT GUESSWORK: Add up to sixteen 50A sensors to accurately monitor your air conditioner, furnace, water heater, washer, dryer, range, etc. 

  • Power the Vue directly from a 15A or 20A breaker
  • Professional installation recommended
  • Granular 1-second data interval
  • Operates regardless of your utility
  • Add up to sixteen 50A sensors to monitor individual circuits
  • Interact with your Emporia Vue through your mobile device or laptop
  • Real-time monitoring of your energy usage and production with helpful units and measurements
  • Actionable notifications will help you:
    • Conserve energy
    • Lower carbon emissions
    • Increase grid reliability
    • Generate energy savings
    • Shift usage patterns from peak to off-peak
    • Get clear calculations that show your savings when you perform actions recommended by the Emporia Vue

Check out the Technical Specs | Download the Spec Sheet PDF

Vue energy monitor dimensions:

  • 4.1" x 3.1" x 1.1" (105mm x 80mm x 30mm)

200A sensor dimensions:

  • 2.6" x 1.7" x 1.6" (65mm x 44mm x 41mm)
  • Window diameter: 1" (26mm)
  • Cable length: 39" (1m)
  • Connector plug: 3.5mm


    Monitoring Only One or Two of Three Phases

    Questions

    “Because of space constraints, we can only install two current transformers (CTs) to monitor a three-phase circuit. Is there a correction factor we can use to compensate for only monitoring two of the three phases?”

    Suggested reading:
    What are the advantages and disadvantages of prepaid meters?
    4 key elements to consider when buying digital signage ...

    acrel contains other products and information you need, so please check it out.

    “What if we only monitor one of the three phases?”

    Answer

    For balanced three-phase, four-wire (wye) circuits, each CT will measure exactly one-third of the total current. So if you are measuring two of the three phases, you would multiply your results by 1.5 to scale the reading to the correct value. If you only measure one phase, you would multiply by 3 to scale the reading to the correct value.

    Limitations

    There are a few different ways a three-phase circuit can be imbalanced that can cause reduced accuracy with this approach:

    • The load may be imbalanced. Three-phase motors are generally well balanced, but other loads may not be. If your load is actually multiple loads (like monitoring the three-phase service to the floor of a building), then there is a high likelihood of imbalance.
    • The voltages from neutral (or ground) to each phase may be imbalanced. There is always a small amount of imbalance, but there can be more imbalance depending on the service and other loads. For example, if one phase voltage is 1.0% higher than the other phases and you are not monitoring the one phase that is high, your power readings would be 0.5% low.
    • In rare cases, one phase voltage may be grounded (called “grounded delta” or “grounded leg”). In this case, the WattNode meter will measure zero power on the grounded phase, so the easy solution is to monitor the other two phases and eliminate the correction factor of 1.5. In this case, you must monitor both of the active (non-grounded) phases for accurate results.

    Recommendations

    If possible, you should use a hand-held power analyzer or multimeter (DMM) to verify that the load is reasonably well balanced. With the power analyzer, you can measure the power on each phase and compare. With the DMM, you can check the phase-to-neutral or phase-to-ground voltages to ensure they are very similar. If you have a meter with a current clamp, you can also check the current in each phase to verify that they are well balanced.

    Extra Notes

    Doesn’t Blondel’s Theorem allow the use of two CTs to monitor a three-phase three-wire (delta) circuit?

    Yes, it means it is possible to design a meter with only two elements (and only two current transformers) to monitor a three-wire delta circuit. But it does not mean all meters can take advantage of this. In order to utilize Blondel’s Theorem, one of the three phases must be used as a reference point, so that the other two phases are measured relative to this reference point.

    The architecture of WNB and WNC series WattNode meters only allows for ground or neutral as the reference points, not one of the voltage phases. Therefore, Blondel’s Theorem cannot be applied to this series of WattNode meters to allow the use of two CTs for three-wire ungrounded delta circuits. As noted above, if your load is balanced, you may be able to use just one CT and multiply readings by 3. Or use two CTs and multiply the readings by 1.5.

    However, in applications using potential transformers (PTs), the secondary of the PT can be wire to provide a reference point. Therefore, in this application, the WNB and WNC series meters can be used with only two CTs. See Figure 3: Monitoring a Delta Circuit on the Using Potential Transformers page.

    The WND series meters can measure 3-phase 3-wire delta, 4-wire delta, and corner grounded delta services using only two CTs.

    Are you interested in learning more about 3 phase power monitor? Contact us today to secure an expert consultation!

    See Also

    Comments

    0 of 2000 characters used

    All Comments (0)
    Get in Touch

      |   Transportation   |   Toys & Hobbies   |   Tools   |   Timepieces, Jewelry, Eyewear   |   Textiles & Leather Products   |   Telecommunications   |   Sports & Entertainment   |   Shoes & Accessories   |   Service Equipment